{"product_id":"refurbished-digirad-cardius-x-act-spect-ct-system","title":"Refurbished Digirad Cardius X-ACT SPECT\/CT System","description":"\u003cp\u003eQDI offers a refurbished Digirad (Digirad Corporation) Cardius X-ACT (also marketed as Cardius X-ACT+ \/ Cardius 3 X-ACT in regulatory filings) for sale as a dedicated cardiac nuclear medicine camera system. The Cardius X-ACT is a compact, cardiocentric SPECT\/CT solution intended for rapid myocardial perfusion imaging with patient comfort in mind, and QDI provides hands-on service and support for this class of system.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Overview\u003c\/h3\u003e\n\u003cp\u003eThe Cardius X-ACT is a dedicated cardiac SPECT system from Digirad that combines triple-head solid-state digital detectors with an integrated low-dose volume CT (VCT) for co-registered attenuation-corrected imaging. Designed for upright, cardiocentric studies in a small footprint and without the requirement for lead-lined rooms, this Digirad (Digirad Corporation) Cardius X-ACT SPECT\/CT refurbished offering is optimized for short scan times and high-count-rate cardiac protocols.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDetector count: Triple-head (3 detectors).\u003c\/li\u003e\n  \u003cli\u003eDetector technology: Solid-state high-definition detectors (Solidium® \/ Cardius-3 XPO digital detectors; pixelated CsI(Tl) with photodiode readout).\u003c\/li\u003e\n  \u003cli\u003eDetector field-of-view (rectangular per head): 15.8 cm x 21.2 cm (6.2\" x 8.3\").\u003c\/li\u003e\n  \u003cli\u003ePixels per detector: 768; pixel size ~6.1 mm x 6.1 mm.\u003c\/li\u003e\n  \u003cli\u003eEnergy range \/ resolution: 50–170 keV; energy resolution \u0026lt; 10.5%.\u003c\/li\u003e\n  \u003cli\u003eCount-rate capability: \u0026gt;3.5 million counts\/sec (system max count rate listed).\u003c\/li\u003e\n  \u003cli\u003eOrbit radius: 18.8 cm – 35.5 cm (7.4\" – 14\").\u003c\/li\u003e\n  \u003cli\u003eAttenuation correction: Integrated low-dose Volume CT (VCT) \/ fluorescence x-ray attenuation correction (wide 27\" VCT beam FOV described in OEM literature).\u003c\/li\u003e\n  \u003cli\u003eCT \/ X-ray: Low-dose VCT transmission scan; scan time listed ~33–60 seconds; reported wide-beam VCT FOV ~27 inches.\u003c\/li\u003e\n  \u003cli\u003ePatient handling \/ siting: Open upright design with saddle-like chair (upright imaging), patient weight limit ~227 kg (500 lbs).\u003c\/li\u003e\n  \u003cli\u003eRoom \/ power \/ size: Minimum room footprint ~8' x 9' (2.4 m x 2.7 m); system footprint ~96\" x 29\"; power 120 VAC, 20A dedicated line.\u003c\/li\u003e\n  \u003cli\u003eYear introduced: 2008\/2009.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eClinical Applications\u003c\/h3\u003e\n\u003cp\u003eThe Cardius X-ACT is intended primarily for cardiac nuclear imaging workflows where a dedicated cardiac camera provides advantages in speed and patient throughput.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMyocardial perfusion imaging \/ cardiac SPECT (MPI)\u003c\/li\u003e\n  \u003cli\u003eGated SPECT (cardiac function \/ MUGA)\u003c\/li\u003e\n  \u003cli\u003eStress-rest cardiac studies\u003c\/li\u003e\n  \u003cli\u003ePotential for dynamic SPECT and dual-isotope cardiac protocols (noted as supported\/future-capable)\u003c\/li\u003e\n  \u003cli\u003eGeneral cardiac nuclear imaging where a dedicated cardiac camera is appropriate\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy Buy Refurbished from QDI\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePractical value of refurbished equipment: refurbished systems deliver many of the same clinical capabilities as newer units while offering a pragmatic procurement path for hospitals and clinics that need dependable imaging without the lead time and complexity of purchasing new equipment.\u003c\/li\u003e\n  \u003cli\u003eInspection and testing by experienced engineers: every unit is examined and tested by engineers with decades of hands-on nuclear medicine field experience to verify core imaging performance and system integrity.\u003c\/li\u003e\n  \u003cli\u003eReduced downtime through practical support: our small, field-focused team emphasizes realistic, efficient service and troubleshooting to keep systems imaging and reduce operational interruptions.\u003c\/li\u003e\n  \u003cli\u003eStraightforward, honest guidance: we help you evaluate configuration, siting, and clinical suitability for your practice with transparent, practical advice rather than marketing jargon.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOur Team's Expertise\u003c\/h3\u003e\n\u003cp\u003eQDI is a small, hands-on team with decades of real field experience servicing and supporting this class of equipment. We provide spect\/ct system service and support grounded in onsite troubleshooting, component-level knowledge, and practical installations tailored to clinical workflows.\u003c\/p\u003e\n\n\u003cp\u003ePlease contact QDI to discuss configuration options, current availability, siting requirements, and a quote for this refurbished Digirad Cardius X-ACT system. We will work with you to determine the right setup and answer any technical questions.\u003c\/p\u003e","brand":"Digirad","offers":[{"title":"Default Title","offer_id":53559511482684,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0858\/5137\/3884\/files\/system_Cardius_X-ACT__also_marketed_as_Cardius_X-ACT____Cardius_3_X-ACT_in_regulatory_filings.png?v=1784322429","url":"https:\/\/nuclearcamera.com\/products\/refurbished-digirad-cardius-x-act-spect-ct-system","provider":"QDI","version":"1.0","type":"link"}